Yilian Industry
+
  • 65.jpg
  • 900 (1).jpg
  • 900 (2).jpg
  • 900 (3).jpg
  • 900 (4).jpg

T900 series


Classification

Turbine gas starter motor

Product Accessories

Key words:

Yilian Industry

Details Introduction

  • Details
  • Parameter
    • Commodity name: T900 series

    With the maximum power of 55Kw (73.5hp),applicable for starting diesel engines below 320 liters,especially suitable for starting oilfield and marine engines.

    █ Product characteristics

    Modular design

    Turbine technology

    Robust and durable

    Convenient for maintenance

    ◇ Offset design,making it easy to arrange in a small space weight only 33.2kg
    ◇ Pre-engaged design,flexible engagement,effectively prolonging the service life of pinion and flywheel ring gear
    ◇ Free-maintenance,without needing external lubrication
    ◇ Two available output rotation options:dlockwise and counterdlockwise
    ◇ Working pressure range 4-6bar/4-10bar
    ◇ 16 offset angles available for the starter body,and 4 air intake directions optional
    ◇ High-strength metal turbine,suitable for harsher working conditions and air source conditions
    ◇ The part surface has anti-corrosion coating
    ◇ The start control component features high integration and compact structure

    █ Industry application

    █ T912A Series Performance Information

    Product Series

    Pressure Bar
    Bar(psig)

    Max Power
    Kw(HP)

    Speed @Max HP

    rpm

    Breakaway Torque
    Nm(ft-lb)

    Flow @Max HPL

    L ∕s(scfm)

    Weight
    Kg(lbs)

    T912A

    4(58)

    19(25.4)

    1550

    142(105)

    283(601)

    35(77)

    6(87)

    31(41.6)

    1800

    248(183)

    430(913)

    8(120)

    42(56.3)

    1930

    320(236)

    513(1090)

    10(150)

    56(75)

    2060

    417(183)

    627(1332)

    █ T912K Series Performance Information

    Product Series

    Pressure Bar
    Bar(psig)

    Max Power
    Kw(HP)

    Speed @Max HP

    rpm

    Breakaway Torque
    Nm(ft-lb)

    Flow @Max HPL

    L ∕s(scfm)

    Weight
    Kg(lbs)

    T912K

    4(58)

    19(25.4)

    1380

    165(122)

    283(601)

    35(77)

    6(87)

    31(41.6)

    1550

    288(213)

    430(913)

    8(120)

    42(56.3)

    1660

    371(236)

    513(1090)

    10(150)

    56(75)

    1770

    484(357)

    627(1332)

    █ T900 Theoretical Performance Curves

    Performance curve of T912A air starter

    Performance curve of T912K air starter

    █ T920A Series Performance Information

    Product Series

    Pressure
    Bar(psig)

    Max Power
    Kw(HP)

    peed @Max HP

    rpm

    Breakaway Torque
    Nm(ft-lb)

    Flow @Max HPL

    L ∕s(scfm)

    Weight
    Kg(lbs)

    T920A

    4(58)

    31(41.6)

    1970

    255(188)

    428(909)

    35(77)

    6(87)

    55(73.7)

    2050

    410(303)

    593(1260)

    █ T920K Series Performance Information

    Product Series

    Pressure
    Bar(psig)

    Max Power
    Kw(HP)

    Speed @Max HP

    rpm

    Breakaway Torque
    Nm(ft-lb)

    Flow @Max HPL

    L ∕s(scfm)

    Weight
    Kg(lbs)

    T920K

    4(58)

    31(40.7)

    1700

    297(219)

    428(909)

    35(77)

    6(87)

    55(73.7)

    1760

    477(352)

    593(1260)

    █ T900 Theoretical Performance Curves

    Performance curve of T920A air starter

    Performance curve of T920Kair starter

    █ T900 Series Model Coding

    █ Outline drawing of T900 starter (unit:mm)

    █ Attached drawing of T900 direction angle

    █ Assembly explosion diagram of T900 series parts

    T90 Series Turbine Air Starter Service

    Package Model T90-AP

    █ Models and parts of T900 starter service package

    Numbered parts are included in the service package

     

    █ Low Inlet Pressure Starter System Drawing

    █ Dual-starter configuration system diagram

    █ High Inlet Pressure Starter System Drawing

    █ Starting motor+Turning configuration system diagram

     
  •  

    Name

    Model

    Parameter

     

    Relay Valve

    VR60-40/VR60-40E

    Flanged connection,Ports Rc1-1/2"

    Maximum Operating Pressure 15.5bar (225psi) Ambient temperature-30°Cto 120°C(-60°Fto  248°F)

     

    Relay Valve Replacement Kits

    VR10-AP1

    Suitable for VR10-25/VR10-25EV

     

    Solenoid Valve

    VE2-01

    Voltage DC24V,power 8.2W

    Ports G1/8

    Maximum Operating Pressure 10bar (145psi) Ambient temperature-20°Cto 70°C(4°Fto   158°F)

     

    Push-Button Valve

    VH-02

    Ports Rc1/8"

    Maximum Operating Pressure 15.5bar (225psi) Ambient temperature-30°Cto 120°C(-60°Fto  248°F)

    Air Strainer

    AY40B-08

    Threaded connection,ports Rc1-1/2",filtering accuracy:80 meshes

    Maximum Operating Pressure 35bar (508psi)   Ambient temperature-30°Cto 120°C(-60°Fto 248°F)

     

    Strainer Element

    DN40-80B

    Filter precision:80 Mesh,Suitable for 4Y40B-08

     

    Requlator Valve

    AR40A

    Ports Rc1-1/2"

    Maximum air intake pressure 31bar (450psi)

    Pressure regulation range:0.7-16bar(10-250psi) Ambient temperature-18"Cto 79°C(0°F to

    175°F)

     

    lator Valve Replacement Kits AR40-AP1

    AR40-AP1

    Suitable for AR40A

Previous Page

Next Page

Previous Page

Next Page

Address

021-69919570

Address

Room 701, Guyi Building, 4929 Zhennan Road, nanxiang town, Jiading District, Shanghai

Yi Lian Industrial

Pay attention to WeChat public number


Copyright © Website Construction of 2022 Yilian Industry (Shanghai) Co., Ltd  
Power By:www.300.cn